H H. F. F. EN. Device may be connected to or disconnected from a live conductor. Flexible sensors can be connected to or. Hioki is pleased to announce the launch of the AC Clamp Meter F ( featuring true RMS measurement) and the AC Clamp Meter Set. Hioki Clamp On HiTester. Discontinued See: F. Easy Operation ; A rms, clamp aperture: 33 mm (“) diameter; Light – g ( oz).

Author: Dozuru Nenos
Country: Reunion
Language: English (Spanish)
Genre: History
Published (Last): 4 June 2018
Pages: 291
PDF File Size: 17.56 Mb
ePub File Size: 8.9 Mb
ISBN: 896-8-80626-811-6
Downloads: 43055
Price: Free* [*Free Regsitration Required]
Uploader: Vuzuru

Technical Notes No results were found. Usable temperature range Max. As a result, it is becoming difficult to 3208 measurements even with the low-profile jaws as the clamp-on sensor portion of the instrument is known that have been a feature of previous products.

Using series AC clamp meters: In addition to AC current measurement, these clamp meters provide voltage and resistance measurement as well as continuity check functionality. Difference between mean value and true RMS measurement Measurements taken with the Hioki F which uses the mean value method and the the Hioki F which uses 32880 true RMS method are compared.

Providing the finest test equipment solutions since 1992

As a result, it is becoming difficult to measure wires with the low-profile, jaw-type clamp clamp-on current sensor typically used in previous products. For many years, Hioki has supplied clamp-on current meters used in the field to carry out such electrical work.

Cable length mm Maintenance and management of electrical equipment in buildings and at manufacturing plants necessitates current and voltage measurement, and Hioki has long supplied clamp-on meters for use in the field by electrical professionals.

A clamp meter with true RMS measurement capability hiki required in order to accurately measure current under such conditions.

Their compact size, low-profile design, and resistance to both rough handling and extreme temperatures make them essential tools for any electrician. By offering over main products characterized by safety and quality while meeting an expansive range of applications, we aim to contribute to the efficiency and value of our customers’ work in research and development, production and electrical maintenance.

  IMM 0008 GENERIC PDF

Log into your myHioki account to access more technical documents and information where available. Introduction to functionality and measurement methods In addition to AC current measurement, these clamp meters provide voltage and resistance measurement as well as continuity check functionality.

Measurements taken with the Hioki F which uses hloki mean value method and the the Hioki F which uses the true RMS method are compared. Both methods can accurately measure current that takes the form of a distortion-free sine wave, but the mean-value method is incapable of accurate measurement when the waveform is distorted due to use of inverter-equipped devices or switching power supplies.

Furthermore, the CT can be used to measure large currents of up to A. For more information, please contact: Observe the difference between readings from these two types of instruments when measuring a distorted waveform that contains harmonic components such as those produced by inverters and switching power supplies.

Hioki Launches AC Clamp Meter 3280-10F and 3280-20F

As a result, it can be used in even harsher environments. Seminar Schedule No results were found. Easy measurement of tangled wires when used with a flexible current sensor As distribution panels have become smaller in recent years, technicians have increasingly found themselves faced 32880 tangled wiring.

In addition to current measurement, this single instrument delivers voltage measurement, continuity check, and resistance measurement functionality.

AC Clamp Meter | F – Hioki

HIOKI products and services are available around the world through our extensive network of subsidiaries and distributors. HIOKI products and services are available around the world through our extensive network of subsidiaries and distributors. CT Basic specifications Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year Core jaw dia.

  HARROWER INSIDE REPORTING PDF

When connected to an optional flexible current sensor, the F can be used to measure the current flowing in pairs of wires or in tangled or complexly routed wires around which it was not possible to apply a clamp-on sensor in the past. Furthermore, the CT can measure large currents of up to A. For more information, please contact: Basic specifications Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year AC Current User Guides No results were found.

Ability to make measurements in confined locations easily with a flexible current sensor As distribution panels have become smaller in recent years, the density of the wiring they contain has increased. Seminar Videos On Demand No results were found.

The F and F enhance the previous and with a broader range of operating temperatures along with the addition of the CT as an option, making measurement more convenient for customers. Essential for electrical work: The F performs true RMS AC measurement, enabling it to accurately measure waveforms that are distorted due to use of inverter-equipped devices or switching power supplies.

Hioki and Clamp On HiTesters, Hioki – at the Test Equipment Depot

A pocket clamp meter that can use flexible sensors When connected to an optional flexible current sensor, the F can be used to measure the current flowing in hioli of wires or in tangled or complexly routed wires around which it was not nioki to apply a clamp-on sensor in the past. Technicians maintaining electrical equipment in buildings and manufacturing plants need to measure current and voltage. A thin card tester that fits in the pocket with all the capabilities of a clamp meter The F delivers all the functionality of a clamp meter and card tester in the form factor of the latter.